Airhank self fault inspection and maintenance, Airhank Side Channel Blower after delivery or installation, sometimes the system operation can not reach the initial design value, the possible reasons include:

1、Impeller rotation method error

2、Installation site power supply voltage / frequency error

3、The air switch (please select excellent product) is old, damaged or of poor quality, and the type selection is wrong

4、Improper installation of high pressure fan and fan pipe

5、Application system design error

6、Application system aging

7、Control error

8、Wrong selection of high pressure air blower

9、Combination of multiple factors

Noise

numberSource of occurrenceCause
A1Impeller impact
Air inlet and outlet or pump body
The impeller is impacted by foreign matters, resulting in eccentricity and unbalance of the impeller.
The air inlet and outlet or pump body are damaged.
The impeller is damaged or worn.
The bearing is damaged.
The bearing and rotor or bearing seat are worn and loose.
The rotor is deformed or damaged.
The rotor or bearing is eccentric.
A2The wind speed is too fast, there is a sharp soundThe inlet and outlet ducts are too small.
The cross-sectional area of import and export is too small.
The radius of fan elbow is too small.
The fan pipe has sharp shrinkage or expansion.
No fan built-in muffler installed
A3leakThe inlet and outlet ducts are too small.
There are holes or cracks in the fan pump body or pump body.
There is leakage in the system pipeline.
There is leakage at the inlet and outlet pipe joints of the fan.
A4VibrationThe fan is not fixed.
The fan pipe is not fixed.

B-Insufficient air volume

numberSource of occurrenceCause
B1Air blower itselfAir blower speed too low (voltage too low, frequency error).
The impeller and pump body are blocked by foreign matters.
Wrong installation of Air blower parts (impeller, pump body, pump cover).
Improper accessories of Air blower inlet and outlet (valve, pressure relief valve, etc.)
Internal muffler seal damaged.
The axial seal of fan is damaged.
Wrong running direction.
B2Duct systemThe actual pressure loss is higher than the estimated value.
There is leakage on the side of service pipe.
There is leakage at the pipe connection (it may also be at the built-in muffler or flange of the Air blower).
The air inlet and outlet pipes are blocked.
B3Filtration systemFilter clogged.
The type selection of filter is wrong, the filtering area of filter element is insufficient, and the filter element conforming to the air volume and pressure loss of fan should be replaced.
B4There is a barrier.The air inlet is blocked by foreign matters.
Serious shrinkage of air inlet pipe of  Air blower.

C-Insufficient air pressure or vacuum

Due to the lack of proper equipment, measuring instruments and piping methods in the project site, the measured values on site are different from those of Airhank test, so few test data are completely consistent with Airhank data. In addition, pay attention to the influence of air density, wind speed, atmospheric pressure and temperature on the system.

numberSource of occurrenceCause
C1Gas densityInlet air temperature too high.
Application in high altitude area.
C2systemExcessive resistance loss of application system.
Control valve not open or damaged.
C3Air blower itselfThe impeller or air inlet is blocked.
After the Air blower is disassembled, the installation is wrong.
The motor coil is aging and damaged.
Air blower speed too low

D- The fan doesn't work

numberSource of occurrenceCause
D1Motor or circuitThe power supply line or switch is short of phase, and the motor is short of phase.
The power supply voltage does not conform to the voltage of the air blower, and the power is not delivered as required.
Overload protector circuit breaker protection.
The voltage is insufficient, or the line is too long, and the voltage drop is too large.
Poor heat dissipation of the motor, high ambient temperature and motor burnout.
D2MechanicsThe impeller is damaged, causing the machine to lock.
The bearing is damaged and the motor cannot be started.

E-Excessive current

numberSource of occurrenceCause
E1air blowerThe working wind speed is too fast.
The air blower shall be applied with non rated value of working point.
E2systemAir blower piping too small.
Excessive resistance loss of application system.
The air inlet and outlet of the Air blower are completely closed.
Pipeline valve not opened (ball valve, check valve, etc.)
E3Gas densityThe air density is lower than the standard atmospheric pressure.
E4Air blower selectionAir blower selection error, according to the maximum working pressure selection.
The loss of pipeline resistance is not considered and there is no surplus in the selection.
E5Measurement errorWrong selection of vacuum gauge or pressure gauge for test.
  Wrong selection of current meter for measurement.

F-High  Air blower temperature

numberSource of occurrenceCause
F1System and environmentInlet air temperature, ambient temperature too high.
Air blower overload, over rated current operation.
Installation space is too small, poor heat dissipation.
F2electric machineryLow operating frequency.
Motor operation in phase loss.
The motor starts frequently.

G-Air blower vibration

numberSource of occurrenceCause
G1airflowThe Air blower is overloaded or surge in the working area.
Influence of system vibration or high pressure source on Air blower.
G2Dynamic and static unbalance of impeller and rotorForeign matter in impeller.
Impeller wear, corrosion and foreign body impact.
Balance piece falling.
The oil seal is worn.
Rotor eccentricity.
G3LooseningThe fixing screw of impeller is loose.
The screw of fan mounting base is loose.
Motor back cover screw loose.
The screw of pump body is loose.
G4Motor and external influenceImproper fixing of air blower and mounting base.
Improper connection of inlet and outlet pipes of air blower
Motor phase imbalance.
Single phase motor capacitor damage.

H-Frequency converter

numberSource of occurrenceCause
H1Unable to start or skip protectionParameter setting, acceleration time is too short.
Parameter setting error(for the above problems, please contact the inverter sales company or refer to the inverter manual).

Contact us quickly

Do you have any questions about air drying system and fluid solutions,Contact:+86 (0769) 2311 5899 Mail:hank@airhank.com

*Please fill in the requirement information carefully,We will contact you within 24 hours.

东莞市汉克机电科技有限公司

Dongguan Airhank Electrical Technology Co., Ltd.

15 years focus on air drying and fluid solutions

Address:3/F, Wanhang Industrical Park, Niushan New Village,Dongcheng Street,
Dongguan City,
Guangdong Province,
China

Mobile:+86 15920245670

Fax:+86 (0769)2311 5099

E-mail:yana@airhank.com

COPYRIGHT © 2014-2017 Dongguan Airhank Electrical Technology Co., Ltd. All Rights Reserved.  

Dongguan Airhank Electrical Technology Co., Ltd.

3/F, Wanhang Industrical Park, Niushan New Village,Dongcheng Street,
Dongguan City,
Guangdong Province,
China